Abstract
A simple and sensitive gas chromatography method for the simultaneous determination of esbiothrin and D-acetylene C permethrin in electric-mosquito coils using palmitic acid isopropyl as an internal standard was developed. The electric-mosquito coil samples were extracted with petroleum ether (60-90 °C) and then centrifuged at 2,000 r/min for 2.0 min. The supernatant liquids were collected into a glass bottle and 2.0 μL of it was injected into the gas chromatograph. The results showed that the means recoveries of esbiothrin and acetylene c permethrin ranged from 100.2% to 99.8%. The relative standard deviation (n=10) of allylic permethrin and acetylene C permethrin was 0.44% and 0.26%, respectively. This method is a viable alternative tool to the existing gas chromatography methods for analyzing the content of allylic permethrin and D-acetylene C permethrin in electric-mosquito coil samples.
Original language | English |
---|---|
Pages (from-to) | 228-230 |
Number of pages | 3 |
Journal | Korean Journal of Chemical Engineering |
Volume | 27 |
Issue number | 1 |
DOIs | |
State | Published - Jan 2010 |
Bibliographical note
Funding Information:This research was supported by Basic Science Research Program through the National Research Foundation (NRF) of Korea funded by the Ministry of Education, Science and Technology (2009-0072787).
Keywords
- Acetylene C Permethrin
- Electric-mosquito Coils
- Esbiothrin
- Gas Chromatography