Abstract
This work presents an analysis of the dynamic behaviour of a HRSG (heat recovery steam generator) during start-up. A calculation program based on a quasi-steady method is constructed. A typical high-pressure HRSG is designed conceptually and analysis is performed to examine the influence of the gas inlet condition of the HRSG on its start-up behaviour. Effects of the gas turbine operation mode and the gas bypass are analysed. In addition, the water level control during start-up, which is one of the most important facts in the real plant operation, is simulated. Through a parametric calculation, the effect of the control parameters on the start-up behaviour is analysed and examples of optimum control are demonstrated.
Original language | English |
---|---|
Pages (from-to) | 137-149 |
Number of pages | 13 |
Journal | International Journal of Energy Research |
Volume | 24 |
Issue number | 2 |
DOIs | |
State | Published - Feb 2000 |
Externally published | Yes |
Keywords
- Analysis
- HRSG
- Start-up
- Water level control